Electrosurgical Generator – VIP ESU
Versatile Design |
of generator helps to perform specialized procedures like cardiovascular, TURP, neuro, thoracic, cancer, endoscopic, laproscopic, hysteroscopy, plastic and reconstructive. |
Isolated design |
directs current return to the generator significantly reducing risks of alternate site burns. |
Portable design |
permits surgeon to carry the unit from hospital, to perform specialized surgical procedures |
Economical equation |
in favour of both manufacturer and surgeons. |
Safety |
the most essential feature in every electrosurgical unit. Sanjeevani's body protected & cardiac protected design, safeguards the O.R. team members. |
User friendly |
operating controls of unit, helps O.R. staff to set the parameters according to the procedures. |
Sanjeevani™ is a complete electrosurgical generator to meet the needs of the surgical team of hospitals & day care based surgery centres. Sanjeevani™ VIP ESU features safety and performance, including isolated output and independent activation of accessories, which substantially reduces the risk of uncalled burns.
Electrosurgical Accessories
|
Sanjeevani™ is associated with extensive array of in house developed electrosurgical accessories like monopolar foot switch, bipolar foot switch, autoclavable foot controlled pencil, autoclavable bipolar forceps, S.S. patient plate and imported hand controlled and foot controlled pencils, speciality electrodes, disposable pregelled patient plate. Quality and compatibility is ensured when your electrosurgery system bears the name Sanjeevani™. |
![]() |
|
Range of autoclavable bipolar forceps. | Electrosurgical pencils with speciality electrodes. |
![]() |
|
Monopolar and Bipolar foot Switch | Pregelled and stainless steel patient plates |
Salient Features |
|
Specifications | |
Input : | 230 V AC |
Output wave forms
|
||||
Monopolar
|
Bipolar
|
|||
Pure cut | Non modulated, 500 kHz. | Pure | Non modulated, 500 kHz. | |
Blend 1 | Modulated,500 kHz with 40% hemostasis | Blend 1 | Modulated,500 kHz with 40% hemostasis added | |
Blend 2 | Modulated,500 kHz with 60% hemostasis | Blend 2 | Modulated,500 kHz with 60% hemostasis added | |
Soft Coag | Modulated with 450 kHz | |||
Fulguration | Modulated with 450 kHz |
Output characteristics |
|||||
Mode
|
Vp-p max
|
Rate & Load
|
Power max (Watts)
|
Crest Factor
|
|
Monopolar
|
Pure cut | 2800 | 500 | 300 | 1.9 @ 100 w |
blend 1 | 3200 | 500 | 250 | 3.0 @ 100 w | |
blend 2 | 3200 | 500 | 200 | 3.3 @ 100 w | |
fulguration | 5000 | 500 | 120 | 5.5 @ 50 w | |
soft coag | 4000 | 500 | 80 | 4.5 @ 50 w | |
Bipolar | pure | 800 | 100 | 70 | 2.0 @ 40 w |
blend 1 | 1000 | 100 | 50 | 2.2 @ 25 w | |
blend 2 | 1000 | 100 | 40 | 2.4 @ 40 w |
High frequency leakage :- | less than 150 mA rms |
Cooling :- | Forced convection cooling by silient fan. |
Mechanical dimentions :- | 130 x 340 x280 mm (h x w x l) |
Weight :- | 9.5 Kg. (w/o accessories) |