D4 Surgicals of India. is a Manufacturer and Exporter of Anesthesia Apparatus. These Anesthesia Apparatus can be made as per Customers specifications if required at an extra cost. D4 Surgicals of India. provides Anesthesia Apparatus to suit the requirements of each and every medical profession. These Anesthesia Apparatus are used in most of the Indian hospitals and Dispensaries. D4 Surgicals has also earned a good reputation from the international community as one of the best quality Anesthesia Apparatus Manufacturer from India. While Manufacturing these Anesthesia Apparatus best quality standards are followed.
D4S MK III 'S' Anesthesia Apparatus
D4S MK III 'M' Anesthesia Apparatus
FEATURES
|
SPECIFICATION
|
|
Construction | Tabular, Rigid, Complete Stainless Steel Sections or Electrostatically Powder Coated Mild steel sections. Rigid stainless steel top tray (size 597mm x 360 mm) Extended rear platform for two 10 Ltr. water capacity cylinders. | |
Mobility | Four large diameter Anti static Castor wheels with double ball bearing for anti-friction movement. Front Castors have break. | |
Colour Coded Cylinder Yokes |
Gas specific(Pin-indexed) Yokes with sliding clamping bars for easy handling. Two each for oxygen and nitrous oxide (5 litre water capacity) cylinders [Cylinders to be ordered separately) |
|
Colour coded & Pressure Gauges | Large diameter (63 mm) two each for Oxygen and Nitrous oxide, fitted at convenient angle for high visibility and clarity. | |
Regulators |
Designed for higher efficiency and reliability; two each for Oxygen and Nitrous oxide. Nitrous oxide regulators are activated only when Oxygen regulators are pressurised to minimise the risk of administering 100% nitrous oxide. |
|
OFWD (Oxygen Failure Warning Device) | Pneumatic device which activates audio-visual alarm when oxygen supply pressure falls to 205 kPa. | |
Rotameters |
Long (230 mm) rotating bobbling flowmeters calibrated in double/ triple scale for accuracy and clarity in reading with Luminous Back Plate which highlights rotating Bobbin even in darkened O.T. Oxygen : 100 ml/min to 8 liters/min Nitrous Oxide : 200 ml/min to 12 liters/min |
|
Vaporisers | One Plenum type Ether Vaporiser fuly made in Brass & Copper and Goldman Halothene Vaporiser supplied as standard. Space for more vaporiser of choice is provided. | |
Non-return cum pressure Relief Valve | Minimises risk of backflow of gases; blows off when pressure exceeds 200 cm of water column. | |
Breathing Attachment |
Standard magill's Circuit or Bains Circuit, Jackson Rees Circuit with changeover unit (open circuit to closed circuit & Vice versa). Emergency Oxygen flush at table top level. |
|
Accessories |
|
|
Circle Absorber | Complete Brass Body Circle Absorber with visible Inspiratory and Expiratory Valve, Transperent Double chamber Sodalime Cannister which can be easily reversed and fitted. A bypass controlled through lever to divert gas flow from Sodalime Cannister when not in use. A Circuit compramising- 2 corrugated Hoses attached to Swivel 'y' Piece and a 2 Ltr. Bag with hose. | |
Dimensions | ||
Height | 156 cm | |
Depth | 66 cm | |
Width | 80 cm | |
Weight (Unpacked) | 70 kg |
D4S MK III (ES) – Stainless Steel Trolley
D4S MK III (EM) – M.S. Powder Coated Trolley
Standard Apparatus with sturdy built and aesthetic look having all major features such as Rotameter Set, Plenum Type Ether Vaporiser fully made in brass, Goldman Halothene Vaporiser, Non-Return cum pressure relief valve, Outlet with Emergency oxygen Flush at table top level, Mox Oxygen connection unit, Magill's OR Bain Circuit, 60 psi Oxygen outlet port with Flowmeter and Humidifier Bottle, with safety features such as Nitrous oxide Cut -off system & Oxygen failure warning device and standard spares.
Note : Provision to attach circle absorber.
D4S Basic 'S2' Apparatus – Stainless steel trolley
D4S Basic 'M2' Apparatus – M.S. Powder Coated Trolley
A compact, aesthetic and sturdy apparatus ensuring continuous Oxygen supply arrangement with basic features like Rotameter Set, Plenum Type Ether Vaporiser fully made in brass, Goldman Halothene Vaporiser, Non-Return cum pressure relief valve, Outlet with Emergency oxygen Flush at table top level, Mox Oxygen connection unit, Magill's OR Bain Circuit, 60 psi Oxygen outlet port with Flowmeter and Humidifier Bottle, with safety features such as Nitrous oxide Cut -off system & Oxygen failure warning device and standard spares.
Note :
- Provision to keep two 10 Ltr. water capacity cylinders.
- Provision to attach circle absorber.
D4S Basic 'S1' Apparatus – Stainless steel trolley
D4S Basic 'M1' Apparatus – M.S. Powder Coated Trolley
A compact, aesthetic and sturdy apparatus with basic anaesthesia components featuring Rotameter Set, Plenum Type Ether Vaporiser fully made in brass, Goldman Halothene Vaporiser, Non-Return cum pressure relief valve, Outlet with Emergency oxygen Flush at table top level, Mox Oxygen connection unit, Magill's OR Bain Circuit, 60 psi Oxygen outlet port with Flowmeter and Humidifier Bottle, with safety features such as Nitrous oxide Cut -off system & Oxygen failure warning device and standard spares.
Note :
- Provision to keep two 10 Ltr. water capacity cylinders.
- Provision to attach circle absorber.
D4S Economy 'S' Apparatus- Stainless steel trolley
D4S Economy 'M' Apparatus- M.S. Powder coated trolley
A most economical compact apparatus with basic anaesthesia components featuring – Rotameter Set, Plenum Type Ether Vaporiser fully made in brass, Goldman Halothene Vaporiser, Outlet with Emergency oxygen and Relief Valve at Vaporiser level , Mox Oxygen connection unit, Magill's OR Bain Circuit with safety features such as Nitrous oxide Cut -off system & Oxygen failure warning device and standard spares.
Thus making it most cost effective apparatus without compromising safety features.
Note :
- Provision to keep two 10 Ltr. water capacity cylinders.
- Provision to attach circle absorber.
D4S Portable Anaesthesia Apparatus
Simple, safe, reliable, complete stainless steel compact structure making it a good portable, easy to transport model with features as Standard Rotameter, Goldman Halothene Vaporiser, Outlet unit with Relief Valve and Emergency Oxygen flush, Magill's OR Bain Circuit, Seperate Oxygen and Nitrous oxide Preset regulators with Coloured Coded Tubings and diffrent end fittings to avoid accidental interchangeability, Nitrous Cut -off system & standard spares.
OPTIONAL :
1. Hypoxia Guard with ORC facility at Rotameter
Compact Redction Gear Mechanism (No Link Chain) which ensures a minimum of 25% (± 5%) Oxygen Concentration in gas mixture which can be raised anywhere in the range of 25% to 100%
2. Mainstream Oxygen Monitor
In-built Oxygen Concentration Monitor measures the oxygen Concentration directly in the breathing system at patient end with Audio-Visual Hypoxia Alarm.
3. Medical Gas Delivery System
WE undertake installation of Central Pipeline for Medical Gases, Vacuum and compressed Air to wards, O.T.'s and I.C.U.'s which is becoming essential requirement in Hospital and Nursing Home.
NOTE : To Acheive users requirements we are flexible to fabricate special trolleys other than standard one and manufacture apparatus having specific required components at an extra cost